Evaluation of three methods for detecting low-level bacterial contamination in intravenous solutions
Abstract:
The accuracy of three sterility-testing methods in detecting low-level contamination in deliberately contaminated intravenous solutions was studied. One-liter bags of 5% dextrose (D5W) and 0.9% sodium chloride (saline injections were contaminated with Staphylococcus epidermidis and Pseudomonas aeruginosa; approximately 10(1) viable bacteria were injected into each bag. Two membrane-filtration methods (Ivex-2 and Addi-Chek) and one aliquot method [twice concentrated trypic soy broth (2X-TSB)] were used to test each of 10 diliberately contaminated solutions for both D5W and saline; 500 ml of each liter bag was filtered or added to 2X-TSB. Incubation containers were stored at 37 degrees C and inspected at 24, 48, and 72 hours for turbidity. There was no significant difference among the three methods in the detection of contaminated saline solutions. The Addi-Chek system was significantly less effective in detecting contamination in D5W than either of the other methods. It is concluded that the Ivex-2 system is accurate and the easiest-to-use system of the three tested.
More Related Videos
11:28A Reference Broth Microdilution Method for Dalbavancin In Vitro Susceptibility Testing of Bacteria that Grow Aerobically
Published on: September 9, 2015
09:07Direct Microbial Identification using An Automated Microbial Identification System to Facilitate the EUCAST RAST Method Without Mass Spectrometry
Published on: May 24, 2024
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Automated Microbial Diagnostics