Noninvasive Doppler determination of cardiac output in man. Clinical validation
Abstract:
A noninvasive technique for assessing cardiac output (CO) was evaluated by comparing it with thermodilution determinations in patients in the intensive care unit. The new method uses pulsed ultrasound to measure aortic diameter and continuous-wave Doppler ultrasound to obtain aortic blood velocity. An initial study evaluating just the velocity measurement showed that changes of the Doppler index of output (DI) correlated well with those of thermodilution cardiac output (TDCO). Linear regression analysis yielded delta DI = 0.87 delta TDCO + 0.14 (r = 0.83, n = 95). Using a university research instrument these measurements were possible in 54 of 60 patients (90%). A second study using a prototype commercial device incorporated the diameter measurement. Ultrasonic cardiac output (UCO), calculated as the time integral of velocity multiplied by the aortic area, was compared to TDCO. The data, obtained from 45 of 53 patients (85%), are described by the linear regression UCO = 0.95TDCO + 0.38 (r = 0.94, n = 110) over a range of 2-11 l/min. Patients with aortic stenosis, aortic insufficiency or a prosthetic valve have been excluded from the second study due to conditions likely to violate the assumptions upon which the calculation of absolute cardiac output is based. These results indicate that accurate CO can be measured by noninvasive ultrasound in most patients. The technique may be useful for extended CO monitoring in acute care patients and for CO assessment in many other types of patients undergoing diagnostic studies and therapeutic interventions.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...