Tonal masking and frequency selectivity for the monaural and binaural hearing systems
Abstract:
A series of masking experiments was performed with the aim of comparing frequency selectivity for the monaural and binaural systems. The masking stimulus used in this study combined a sinusoid, which was gated simultaneously with the signal, with a continuous broadband noise. Signal frequency was fixed at 500 Hz. In one condition, the tonal masker and noise were interaurally in phase and the signal was phase reversed. In a second condition, noise, tonal masker, and signal were presented to one ear alone. Signal thresholds were obtained as a function of masker frequency for these two conditions. After making an appropriate selection of noise levels, masking functions for the monaural and binaural system conditions were found to agree closely except for a region about their tips where the binaural condition was more detectable. Two possible interpretations of these results are discussed. Either the monaural and binaural systems contain filters each which have similarly shaped skirts, or the frequency selectivity observed under both diotic and dichotic conditions (for large frequency separations of masker and signal) reflect the operation of a common peripheral filter.