Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

A quick and efficient way to pool platelets.

B C Gorgone, F R Coliano, S A Tuttle

    Transfusion
    |January 1, 1983
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The influence of beam energy on the outcome of postoperative radiotherapy in head and neck cancer patients: secondary analysis of RTOG 85-03.

    International journal of radiation oncology, biology, physics·2000
    Same author

    Is a surgical resection leaving positive margins of benefit to the patient with locally advanced squamous cell carcinoma of the head and neck: a comparative study using the intergroup study 0034 and the Radiation Therapy Oncology Group head and neck database.

    International journal of radiation oncology, biology, physics·1993
    Same author

    Human bone marrow depleted of CD33-positive cells mediates delayed but durable reconstitution of hematopoiesis: clinical trial of MY9 monoclonal antibody-purged autografts for the treatment of acute myeloid leukemia.

    Blood·1992
    Same author

    Adjuvant chemotherapy for resectable squamous cell carcinomas of the head and neck: report on Intergroup Study 0034.

    International journal of radiation oncology, biology, physics·1992
    Same author

    Phase II trial of ifosfamide and mesna in previously treated patients with non-Hodgkin's lymphoma: Cancer and Leukemia Group B study 8552.

    Hematological oncology·1991
    Same author

    Waldenström's macroglobulinemia: long-term results with the M-2 protocol.

    Cancer investigation·1991
    Same journal

    Spray dried plasma manufactured from apheresis and whole blood derived plasma.

    Transfusion·2026
    Same journal

    Identification of a novel ABO*A1.01 allele with c.562C>T (p.Arg188Cys) mutation associated with A<sub>el</sub> phenotype in a Chinese individual.

    Transfusion·2026
    Same journal

    AABB survey on directed blood donation practices.

    Transfusion·2026
    Same journal

    Cost analysis considerations for red blood cell matching to mitigate alloimmunization in patients with sickle cell disease.

    Transfusion·2026
    Same journal

    A novel translation initiation codon single nucleotide variant of the SLC14A1 (c.2T>G) from a Chinese blood donor with Jk(a-b-) phenotype.

    Transfusion·2026
    Same journal

    Size (and frequency) matter: Evaluating the best management practices for blood products with spotty demand.

    Transfusion·2026
    See all related articles

    A new vacuum system efficiently pools platelet concentrates, saving significant time without causing platelet loss. This method is comparable to traditional techniques, offering a practical solution for blood banking.

    Area of Science:

    • Transfusion Medicine
    • Hematology
    • Biotechnology

    Background:

    • Pooling multiple platelet concentrates is a common practice in transfusion medicine to achieve desired therapeutic doses.
    • Traditional manual pooling methods can be time-consuming and may potentially lead to product loss.

    Purpose of the Study:

    • To present an easy, efficient, and optimized method for pooling multiple platelet concentrates.
    • To evaluate the time efficiency and potential for platelet loss using a modified laboratory vacuum system for pooling.

    Main Methods:

    • Adaptation of a laboratory vacuum system for the process of pooling platelet units.
    • A laboratory time study was conducted to compare the vacuum pooling method with traditional manual methods.
    • Statistical analysis (two-sample t-test) was used to assess differences in platelet loss.

    Related Experiment Videos

    Main Results:

    • The vacuum pooling system significantly shortened the process of pooling platelet units.
    • Time savings of 27.5% and 35.9% were observed when pooling four-unit and six-unit platelet packs, respectively.
    • Platelet loss using the vacuum method was statistically indistinguishable from the manual method (p = 0.4).

    Conclusions:

    • The adapted laboratory vacuum system provides an efficient method for pooling platelet concentrates.
    • This method achieves significant time savings without compromising product integrity or increasing platelet loss.
    • The vacuum pooling technique offers a practical and effective alternative for blood banking procedures.