Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
A computerized system for continuous physiologic data collection and analysis: initial report on mean arterial blood
Abstract:
A system for continuous measurement and analysis of mean arterial blood pressure (MABP) by microcomputer is presented. The system allows prolonged recording and maintenance of fine detail by sequential evaluation and storage of up to 3,600 data points per hour. Fifteen preterm appropriate-for-gestational-age (AGA) infants weighing less than or equal to 1,500 g (very low birth weight) who were free of pulmonary and neurologic disease were monitored continuously from birth to 5 days of age. MABP was recorded via an umbilical arterial catheter with a pressure transducer and module interfaced with the microcomputer. Software was developed to analyze this stored data rapidly. MABP was found to correlate significantly with gestational age from 3 to 15 hours of age (P less than .05). Significant correlation was rare after 20 hours of age. MABP increased as a function of postnatal age in 11 infants. This increase was greater (0.31 to 0.54 mm Hg/h) for the least mature infants (27 to 29 weeks of gestation). The increase for the most mature infants (31 to 32 weeks of gestation) was low (0 to 0.24 mm Hg/h), and in three infants a small negative slope was seen. The steep rise in MABP during the first 40 hours of life in the least mature infants may be due to the perfusion requirements of extrauterine life. These pressures may be at or near the threshold for rupture of immature vascular beds such as are found in the subependymal germinal matrix and thus predispose to intraventricular hemorrhage.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure