Related Experiment Video
Updated: Aug 16, 2026

Subtype-specific Optical Action Potential Recordings in Human Induced Pluripotent Stem Cell-derived Ventricular Cardiomyocytes
Published on: September 27, 2018
Long-term recording of monophasic action potentials from human endocardium
Abstract:
In 36 patients undergoing routine cardiac catheterization, a new "contact electrode" catheter technique was used to record monophasic action potentials (MAPs) from right atrial and right and left ventricular endocardial sites without the application of suction. Although of smaller amplitude, typically ranging from 15 to 40 mV, and of different reversal ratio (33 +/- 3%), MAP recordings closely resembled transmembrane action potentials in configuration and duration. Continuous MAP recordings of stable amplitude and, during regular pacing, of constant duration (+/- 1% at 90% repolarization) could be made from the same endocardial site for test periods of 1 hour (n = 4), permitting direct evaluation of the effect of cycle length alterations on local myocardial repolarization. A linear relation was found between MAP duration and basic cycle length varying from 350 to 700 ms. These rate-dependent changes in MAP duration were caused by a change in the slow phase of repolarization (phase 2), whereas the slope of rapid repolarization (phase 3) was unaltered. Single premature MAPs or MAPs after a pause showed changes in both phases. No MAPs could be recorded in areas of infarcted, aneurysmal myocardium, indicating that local viable myocardium is a prerequisite for the generation of the monophasic signal. Thus, in human subjects this catheter permits safe, long-term recording of MAPs which, although of smaller amplitude than transmembrane action potentials, bear appropriate and predictable phase relations. Such recordings may be useful in evaluating changes in local myocardial electrical activity induced by pacing or resulting from myocardial disease, or both.
More Related Videos
08:53Human iPSC-Derived Cardiomyocyte Networks on Multiwell Micro-electrode Arrays for Recurrent Action Potential Recordings
Published on: July 15, 2019
10:41Laser-Induced Action Potential-Like Measurements of Cardiomyocytes on Microelectrode Arrays for Increased Predictivity of Safety Pharmacology
Published on: September 13, 2022
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials