The respiratory inductive plethysmograph: bands versus jerkins.

S Spier, S England

    The American Review of Respiratory Disease
    |June 1, 1983
    PubMed
    Summary

    The respiratory inductive plethysmograph (RIP) measures breathing via body movements. The older jerkin RIP design is more accurate for prolonged studies than the newer separate band version.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The Emirates Mars Mission.

    Space science reviews·2022
    Same author

    Mars's Dayside Upper Ionospheric Composition Is Affected by Magnetic Field Conditions.

    Journal of geophysical research. Space physics·2020
    Same author

    MAVEN observations of the response of Mars to an interplanetary coronal mass ejection.

    Science (New York, N.Y.)·2015
    Same author

    Early MAVEN Deep Dip campaign reveals thermosphere and ionosphere variability.

    Science (New York, N.Y.)·2015
    Same author

    Purification of plastids from higher-plant roots.

    Planta·2013
    Same author

    Delayed ulnar nerve palsy secondary to ulnar artery pseudoaneurysm distal to Guyon's canal following penetrating trauma to the hand.

    Annals of the Royal College of Surgeons of England·2013

    Area of Science:

    • Respiratory physiology
    • Biomedical engineering

    Background:

    • Respiratory inductive plethysmography (RIP) is a non-invasive method for measuring ventilation.
    • RIP utilizes inductance coils to track rib cage and abdominal movements.

    Purpose of the Study:

    • To compare the accuracy of two versions of respiratory inductive plethysmograph (RIP) inductance coils.
    • To determine the optimal RIP configuration for prolonged respiratory monitoring.

    Main Methods:

    • The study involved 12 subjects undergoing overnight respiratory monitoring.
    • Accuracy was assessed by comparing RIP-measured tidal volumes with spirometry.
    • Two RIP coil configurations were tested: a one-piece jerkin and separate bands.

    Main Results:

    • The jerkin RIP configuration demonstrated high accuracy, with 87% of breaths measured correctly.
    • The separate band RIP configuration showed lower accuracy, with less than 50% of tidal volumes being accurate.
    • The separate bands exhibited greater movement compared to the jerkin design.

    Conclusions:

    • The one-piece jerkin respiratory inductive plethysmograph (RIP) is recommended for prolonged studies due to its superior accuracy.
    • The separate band design's increased movement may compromise measurement reliability.
    • Further research may be needed to optimize the separate band RIP system.