Endocarditis due to an atypical mycobacterium following porcine heart valve replacement
Abstract:
Following aortic valve replacement with a porcine xenograph, a patient developed endocarditis complicated by a fistula between aorta and right ventricle. The xenograph was replaced by a mechanical valve and the fisutla oversewn. No organisms were cultured but acid-fast bacilli were seen in the aortic wall and excised valve tissue. It is likely that these were contaminants of the porcine prosthesis.
Insights
A patient developed endocarditis after aortic valve replacement with a porcine xenograph, leading to a fistula. Acid-fast bacilli, likely contaminants, were found, prompting valve replacement and fistula repair.
Area of Science:
- Cardiovascular Surgery
- Infectious Diseases
- Prosthetic Valve Complications
Background:
- Aortic valve replacement (AVR) using porcine xenografts is a common procedure.
- Endocarditis is a serious complication following valve replacement surgery.
- Fistula formation between cardiac chambers and great vessels is a rare but critical complication.
Observation:
- A patient developed endocarditis after AVR with a porcine xenograph.
- The endocarditis complicated by a fistula between the aorta and the right ventricle.
- Acid-fast bacilli were identified in the aortic wall and excised valve tissue, though no organisms were cultured.
Findings:
- The patient underwent successful re-operation with replacement of the xenograph with a mechanical valve.
- The aorto-ventricular fistula was surgically closed.
- The identified acid-fast bacilli were presumed to be contaminants from the porcine prosthesis.
Implications:
- This case highlights the potential for prosthetic material contamination leading to severe complications.
- Early recognition and surgical intervention are crucial for managing complex prosthetic valve endocarditis with fistula.
- Consideration of contaminant organisms in prosthetic valve endocarditis is important for appropriate management.