Comparison of four membrane filter methods for fecal coliform enumeration
Applied and Environmental Microbiology
|April 1, 1982
Summary
The mTEC method offers superior fecal coliform enumeration compared to other membrane filter techniques. It demonstrates high recovery, accuracy, and specificity, making it ideal for water quality testing.
Area of Science:
- Environmental microbiology
- Water quality analysis
- Microbial enumeration techniques
Background:
- Accurate enumeration of fecal coliforms is crucial for assessing water safety.
- Existing membrane filter methods have limitations in accuracy, specificity, and recovery.
Purpose of the Study:
- To evaluate and compare four membrane filter methods for fecal coliform enumeration.
- To determine the accuracy, specificity, upper counting limit, and recovery comparability of each method.
Main Methods:
- Evaluation of m-FC, mTEC, m-FC2, and MacConkey membrane broth methods across six laboratories.
- Assessment of recovery accuracy with pure cultures and temperature-stressed cultures.
- Specificity testing through colony verification and analysis of false positives/negatives.
- Counting range experiments and recovery comparisons using diverse water samples.
Main Results:
- mTEC, m-FC, and m-FC2 methods showed high recovery (89-100%) with pure cultures, while MacConkey was <60%.
- Recovery decreased significantly under temperature stress (10°C).
- mTEC exhibited the highest upper counting limit (130 colonies/filter) and superior recovery from chlorinated effluents.
- m-FC2 had the highest false-positive rate (18%), and MacConkey had the highest false-negative rate (26%).
Conclusions:
- The mTEC method provides the best overall performance for fecal coliform enumeration.
- mTEC offers high recovery, low background colonies, good specificity, accuracy, and a high upper counting limit.