Electron probe and electron energy loss analysis in biology
Related Experiment Video
Updated: Oct 12, 2026

Measurement of Total Calcium in Neurons by Electron Probe X-ray Microanalysis
Published on: November 20, 2013
Abstract:
Methods, applications and limitations of quantitative electron probe analysis, X-ray mapping, electron energy loss analysis and energy filtered imaging are described, with emphasis on the analysis of thin (less than 200nm) cryosections. Energy dispersion electron probe analysis can measure reliably 5 to 10mM/Kg of biologically prevalent elements in 50nm diameter areas of 100 to 150 nm thick cryo sections during 100-300 sec counts. The minimal detectable mass (MDM) with a conventional thermionic electron source is approximately 10(-19)g Fe (100 sec count) and can be reduced to 10(-20)g through the use of a field emission gun (FEG). A spatial resolution of 8.7nm is demonstrated in two-dimensional Fourier transforms of Mo X-ray maps of stained catalase crystals. Significant biological results of quantitative electron probe analysis include the measurement of total Ca released from the Mg and K taken up by the sarcoplasmic reticulum during muscle contraction, and the demonstration that mitochondria do not contribute to the physiological regulation of cytoplasmic free Ca levels in cardiac, vascular smooth and striated muscle. Electron energy loss analysis (EELS) promises a significant improvement in sensitivity for the measurement of Ca; based on statistical errors of the measurement, 250 microM/Kg Ca should be measureable with EELS in 250 sec. through the Ca L-edge loss. The use of a doubly corrected magnetic sector spectrometer as a transmission electron microscope imaging filter outside the microscope vacuum is illustrated, and the resolution of the iron core (7.5nm) and surrounding organic shell of single ferritin molecules is demonstrated in, respectively, iron M and carbon K loss images.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Cryo-electron Microscopy
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab