Improved and rapid high-performance liquid chromatographic assay for 13-cis-retinoic acid or all-trans-retinoic acid
Abstract:
A rapid, specific, and sensitive reversed-phase high-performance liquid chromatographic (HPLC) assay for the quantitative determination of all-trans-retinoic acid (I) or 13-cis-retinoic acid (II) in rat serum without extraction of lyophilization is described. Chromatographic separation from retinol, serum components, and retinol acetate standard was achieved on octadecylsilane-coated particles with acetonitrile-1% ammonium acetate as th eluent. Serum samples (100 microliter) containing as little as 10 ng of retinoid were analyzed. Serum level profiles of rats dosed with the retinoids demonstrated the utility of the assay and indicated elimination half-lives of 0.58 and 0.92 hr for I and II, respectively.