Related Experiment Video
Updated: Sep 29, 2026

Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Properties and an anisotropic model of cancellous bone from the proximal tibial epiphysis
Abstract:
An investigation has been made of the source and magnitude of anisotropic material properties of cancellous bone in the proximal epiphysis of the human tibia. Results are reported for stiffness measurements made in three orthogonal directions on 21 cubes of cancellous bone before testing to failure along one of the three principal axes. The structure is approximately transversely isotropic. Strength and stiffness are linear with area fraction for loading along the isotropic axis. Strength is proportional to stiffness for all directions. A finite element model is proposed, based on experimental observations, which enables one to predict the elastic constants of cylindrically structured cancellous bone in the tibia from morphological measurements in the transverse plane.
Related Concept Videos
Bone Structure
Bone Remodeling
The Bone Matrix
Bone Remodeling and Repair
Spongy Bone
Spongy bone is more porous, and less dense compared to compact bone. It is composed of concentric lamellae that are arranged irregularly to form the trabecular network. In some bones, the spaces between trabeculae contain red marrow, where...
Bone Formation by Endochondral Ossification