Related Experiment Video
Updated: Jul 28, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Comparison of continuous-wave Doppler imaging, oculopneumoplethysmography, and the cerebrovascular Doppler
Abstract:
Previous reports of continuous-wave Doppler imaging have combined that technique with periorbital Doppler studies. In the present report, 75 patients with findings suggestive of cerebrovascular insufficiency were evaluated using continuous-wave Doppler imaging, oculopneumoplethysmography (OPG-G) and the cerebrovascular Doppler examination (CDE). Each test was interpreted independently. Doppler imaging had an overall accuracy of 85%, with a 68% accuracy in identifying 50-70% stenoses and a 69% accuracy in identifying high-grade stenoses (greater than 70%) and occlusion. OPG-G had an overall accuracy of 85%, with a 55% sensitivity for 50-70% stenoses and an 89% sensitivity for high-grade stenoses and occlusion. The CDE had an overall accuracy of 84% and a 50% sensitivity for stenoses of 50-70% and an 88% sensitivity for high-grade stenoses and occlusion. As an independent technique, continuous-wave Doppler imaging achieves an overall accuracy comparable to that of OPG-G or the CDE. Its sensitivity to high-grade stenosis and occlusion, however, is less than that of the other techniques. Since CDE and OPG-G had a 94% sensitivity to carotid occlusion and a combined sensitivity to high-grade stenoses and occlusion of 88% and 89%, respectively, their combined use with Doppler imaging offers sensitivity to and differentiation of stenoses from occlusion.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies VII: Vascular Imaging