Standard waveforms for spirometer testing

J L Hankinson, R M Gardner

    The American Review of Respiratory Disease
    |August 1, 1982
    PubMed
    Summary
    This summary is machine-generated.

    Standardized lung function testing uses patient-representative waveforms to ensure spirometer accuracy. This approach verifies device performance against established American Thoracic Society and Association for the Advancement of Medical Instrumentation standards for reliable clinical results.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The impact of timing modified natural cycle frozen embryo transfer based on spontaneous luteinizing hormone surge.

    Journal of assisted reproduction and genetics·2020
    Same author

    Achievements after Six Years of The International Partnership for Health Informatics Education.

    Yearbook of medical informatics·2016
    Same author

    University of Utah Medical Informatics Research and Training Program.

    Yearbook of medical informatics·2016
    Same author

    Clinical Information Systems - From Yesterday to Tomorrow.

    Yearbook of medical informatics·2016
    Same author

    Maternal polycystic ovary syndrome and the risk of autism spectrum disorders in the offspring: a population-based nationwide study in Sweden.

    Molecular psychiatry·2015
    Same author

    Influence of maternal infections on neonatal acute phase proteins and their interaction in the development of non-affective psychosis.

    Translational psychiatry·2015
    Same journal

    Human lung lysozyme: sources and properties.

    The American review of respiratory disease·2015
    Same journal

    "Immotile-cilia" syndrome and ciliary abnormalities induced by infection and injury.

    The American review of respiratory disease·2013
    Same journal

    Adult criteria for obstructive apnea do not identify children with serious obstruction.

    The American review of respiratory disease·1993
    Same journal

    Cell adhesion molecules and the bronchial epithelium.

    The American review of respiratory disease·1993
    Same journal

    Adhesion molecules and cytokine production.

    The American review of respiratory disease·1993
    Same journal

    Molecular mechanisms mediating lymphocyte recirculation, inflammation, and metastasis formation.

    The American review of respiratory disease·1993
    See all related articles

    Area of Science:

    • Pulmonary Function Testing
    • Medical Device Performance Standards
    • Respiratory Diagnostics

    Background:

    • Current spirometer standards from the American Thoracic Society (ATS) and proposed Association for the Advancement of Medical Instrumentation (AAMI) focus on performance requirements.
    • Accurate spirometry is crucial for diagnosing and managing respiratory diseases.
    • Testing spirometers requires reliable and reproducible test signals that mimic real-world patient conditions.

    Purpose of the Study:

    • To establish a standardized method for testing and qualifying spirometers.
    • To ensure spirometer compliance with ATS and AAMI performance standards.
    • To provide a set of validated waveforms for consistent spirometer evaluation.

    Main Methods:

    • Selection of 24 standard waveforms from a larger dataset of forced vital capacity (FVC) maneuvers.

    Related Experiment Videos

  • Waveforms represent diverse patient abnormalities and a range of test results.
  • Utilized digital mediums to store waveforms for driving mechanical syringes or direct software input for hardware/software testing.
  • Main Results:

    • Each standard waveform is associated with known spirometric parameters.
    • This allows for straightforward verification of spirometer adherence to performance requirements.
    • The selected waveforms provide a robust basis for spirometer calibration and validation.

    Conclusions:

    • The use of patient-derived standard waveforms is the most effective method for testing spirometer performance.
    • This approach ensures spirometers meet critical performance standards for clinical use.
    • The validated waveform set facilitates accurate and reliable lung function assessments.