Successful late non-surgical removal of intracardiac catheter fragment

British Heart Journal
|October 1, 1982
PubMed

Insights

A retained intracardiac catheter fragment was found in a patient over two years after aortic valve replacement. The fragment was successfully removed using a percutaneous catheter technique.

Area of Science:

  • Cardiology
  • Medical Devices
  • Interventional Cardiology

Background:

  • Retained surgical materials pose a risk for patients, potentially leading to complications.
  • Aortic valve replacement is a common cardiac procedure, and catheter use is frequent.

Observation:

  • A patient presented with symptoms suggestive of subacute bacterial endocarditis and supraventricular tachycardia.
  • Extensive investigations and multiple hospital admissions occurred over two years without identifying the cause.

Findings:

  • A retained intracardiac catheter fragment, detached more than two years prior, was identified as the likely cause.
  • Percutaneous catheter retrieval of the fragment was successful, despite the prolonged interval.

Implications:

  • This case highlights the importance of considering retained foreign bodies in patients with unexplained symptoms, even years after procedures.
  • Percutaneous retrieval is a viable option for managing intracardiac foreign bodies, regardless of the time elapsed.
  • Improved imaging and vigilance can aid in early detection of retained intracardiac fragments.