Titrimetric and gravimetric calibration of pipettors: a survey

The American Journal of Medical Technology
|September 1, 1982
PubMed

Related Concept Videos

Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
Titrimetric Methods: Types and Commonly Used Strategies01:08

Titrimetric Methods: Types and Commonly Used Strategies

In chemistry, titrimetric methods are broadly classified into three types: volumetric, gravimetric, and coulometric. Volumetric titrations involve measuring the volume of a titrant of known concentration that is required to react completely with an analyte. In gravimetric titrations, the standard solution reacts with the analyte to form an insoluble precipitate, which is filtered, dried, and weighed. In coulometric titrations, current is applied to an electrochemical reaction until the reaction...
Gravimetry: Overview01:05

Gravimetry: Overview

Gravimetric analysis is a quantitative method where the analyte is isolated and weighed directly or after conversion into a substance of known composition. Gravimetric analysis can be classified as precipitation, electrogravimetry, volatilization, and particulate gravimetry, based on the method used to isolate the analyte.
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Quantitative Analysis01:12

Quantitative Analysis

Quantitative analysis is a technique for measuring the amount of specific constituents in a sample. When the sample's composition is unknown, qualitative analysis is performed first to identify its components, which ensures that the correct substances are measured during the quantitative phase.
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the method...
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...