Contrast media induced serotonin release in human blood
Abstract:
Several contrast media were tested for their ability to release serotonin from whole blood. Renografin-60, Hypaque M-75, Vascoray and Conray were incubated with human blood at 37 degrees C for 60 min. Platelet-poor plasma was analysed for serotonin using a high performance liquid chromatographic technique. Seven non-ionic contrast media were similarly incubated and serotonin levels determined. Ionic contrast media induced a greater release of serotonin compared with non-ionic ones. The amount of serotonin was not proportional to iodine concentration in blood. These results suggest that hypertonic solutions of contrast media produce a physical injury to platelets causing them to release their granular contents.
Related Concept Videos
Microbial Growth Media
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Drugs Affecting GI Tract Motility: Serotonin Receptor Agonists
Energy-releasing Steps of Glycolysis
The first energy-releasing step—the 6th step of glycolysis...
ATP Energy Storage and Release
One example of energy coupling using ATP involves a...
Drugs Affecting Neurotransmitter Release or Uptake