Postenucleation orbital implant extrusion

R Dryden, J Leibsohn

    Archives of Ophthalmology (Chicago, Ill. : 1960)
    |November 1, 1978
    PubMed
    Summary
    This summary is machine-generated.

    Postenucleation orbital implant extrusion may be caused by wound dehiscence and conjunctival epithelial downgrowth. This study introduces a new explanation and a repair procedure for this complication.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Regeneration and health: a structured, rapid literature review.

    Public health·2017
    Same author

    Thoracolumbar kyphosis in patients with mucopolysaccharidoses: clinical outcomes and predictive radiographic factors for progression of deformity.

    The bone & joint journal·2016
    Same author

    Can birth defects be prevented?

    Papua and New Guinea medical journal·1997
    Same author

    Birth defects recognized in 10,000 babies born consecutively in Port Moresby General Hospital, Papua New Guinea.

    Papua and New Guinea medical journal·1997
    Same author

    The relationship between drug and alcohol use and peer group associations of college freshmen as they transition from high school.

    Journal of drug education·1994
    Same author

    Intentional buttonholing of the Hughes' flap.

    Ophthalmic plastic and reconstructive surgery·1993

    Area of Science:

    • Ophthalmology
    • Surgical Pathology

    Background:

    • Postenucleation orbital implant extrusion is a known complication.
    • The exact etiology remains incompletely understood.

    Purpose of the Study:

    • To propose a novel explanation for postenucleation orbital implant extrusion.
    • To describe a surgical technique for managing this condition.

    Main Methods:

    • A prospective clinical study was conducted.
    • Pathological data were analyzed to support the proposed mechanism.

    Main Results:

    • A correlation between wound dehiscence and conjunctival epithelial downgrowth was observed.
    • This sequence is proposed as the primary cause of implant extrusion.

    Related Experiment Videos

    Conclusions:

    • Wound dehiscence followed by conjunctival epithelial downgrowth provides a new framework for understanding implant extrusion.