Related Experiment Video
Updated: Aug 14, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Inaccuracy of liquid crystal thermometry to identify core temperature trends in postoperative adults
Abstract:
In 71 adult postsurgical patients, simultaneous measurement of core (tympanic membrane) and shell (liquid crystal adhesive temperature strip) cutaneous temperature was assessed on admission and every 15 minutes throughout the recovery room stay. Tympanic membrane sensors were inserted into the ear and adhesive temperature strips were applied to the forehead. Although temperature strip temperatures on admission to the recovery room were correlated significantly with tympanic membrane temperatures on admission to the recovery room (r = 0.61, p less than 0.001), subsequent readings 15, 30, 45, and 60 minutes after admission demonstrated decreasing correlation coefficients. Moreover, changes in temperature strip temperatures over the first 15, 30, and 45 minutes of monitoring in the recovery room did not correlate significantly with changes in tympanic membrane temperatures over the same time period. These data suggest that shell temperature (temperature strip) is not a reliable or valid trend indicator of core temperature (tympanic membrane) in postanesthetic adults.
More Related Videos
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
05:43Determination of Continuity Index Values in Atrial Fibrillation Ablation with Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.