Related Experiment Video
Updated: Oct 23, 2025

Dual-color Correlative Light and Electron Microscopy for the Visualization of Interactions between Mitochondria and Lysosomes
Published on: September 27, 2024
Evaluation of reflection interference contrast microscope images of living cells
Abstract:
Reflection contrast microscope methods are generally used for studies of those portions of the cell that are turned towards the glass coverslip, to comprehend the structure of the cytoskeleton and the dynamics of cell movement, as well as formation of cell-glass contacts. In incident illumination only reflected light contributes to picture formation. The intensity of which in the case of observation of unstained cells is small because of small refraction differences. To overcome this problem a reflection contrast system was developed by Leitz according to Ploem [49], in which by using contrast preserving measures the reflection becomes prominent in comparison with the lens reflexes. The emerging pictures are a result of interferences of reflections at glass-cell, cell-culture medium and culture medium-cell interfaces. According to Fresnel's equations the reflected intensity depends on the differences of the particular refractive indices and the thickness of the layers, which determine the phase of interfering beams. In idealized systems of thin films the reflected intensity is a measure for their optical constants. Relative reflection measurements from glass-cell areas is comparison with the known glass-medium reflection, can therefore be revealing as far as refraction index, cell-glass distance or cell thickness are concerned. The estimates by Bereiter-Hahn et al. [15] were made in the assumption of vertical illumination neglecting its actual conical shape: the comparison of two Fresnel functions of cytological relevant measurements show - in accordance with Gingell and Todd [24] - that this is only permitted under certain conditions, depending on the required accuracy of the measurements; an incidence angle of about 30 degrees leads to an error of about 10%, an angle of 50 degrees to more than 50%.
Related Concept Videos
Three-Dimensional Microscopy in Microbiology
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Total Internal Reflection Fluorescence Microscopy
Super-resolution Fluorescence Microscopy

