Electrolyte destruction of lung tissue. Electrochemical aspects
Acta Radiologica: Diagnosis
|January 1, 1980
Abstract:
The electrochemical basis for tissue destruction by electrolysis was analysed. Electrolytic lesions from pig lungs had a higher content of organically bound chlorine than normal tissue and it is suggested that chlorine, liberated at the anode, is the principal agent in the electrolytic destruction of tissue. The electrode systems that were most effective in destroying tissue produced the lesions with the highest content of chlorine. Experiments in physiologic saline established that a current density of 40 mA/cm2 gave the best yield of chlorine.
Related Concept Videos
Electrolysis
30.7K
In a galvanic cell, the electrical work is done by a redox system on its surroundings as electrons produced by the spontaneous redox reactions are transferred through an external circuit. Alternatively, an external circuit does work on a redox system by imposing a voltage sufficient to drive an otherwise nonspontaneous reaction in a process known as electrolysis. For instance, recharging a battery involves the use of an external power source to drive the spontaneous (discharge) cell reaction in...
30.7K
Electrolyte and Nonelectrolyte Solutions
72.3K
Substances that undergo either a physical or a chemical change in solution to yield ions that can conduct electricity are called electrolytes. If a substance yields ions in solution, that is, if the compound undergoes 100% dissociation, then the substance is a strong electrolyte. Complete dissociation is indicated by a single forward arrow. For example, water-soluble ionic compounds like sodium chloride dissociate into sodium cations and chloride anions in aqueous solution.
72.3K
Introduction to Electrolytes
16.8K
In humans, electrolytes play a vital role in various physiological processes. Balancing electrolyte levels is essential for normal body functions; their imbalance can be life-threatening. The major electrolytes include sodium, potassium, chloride, calcium, phosphate, and bicarbonate. They are primarily involved in physiological processes, such as nerve signal transmission, membrane trafficking, muscle contraction, buffering body fluids, and balancing water levels in the body.
Role of Sodium
One...
Role of Sodium
One...
16.8K
Toxic Reactions: Overview
2.5K
When toxic substances penetrate the human body, they disseminate to various tissues, undergoing metabolic changes. This process yields reactive metabolites that may covalently bind with specific target molecules, resulting in toxicity.
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
2.5K
Electrogravimetric Analysis: Overview
834
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
834
Potentiometry: Membrane Electrodes
1.9K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.9K


