Related Experiment Video
Updated: Aug 11, 2026

Analysis of Physiologic E-Selectin-Mediated Leukocyte Rolling on Microvascular Endothelium
Published on: February 11, 2009
Method for the automation of equine differential leucocyte counts
Automated equine differential leucocyte counts using Coulter Channelyzer volume analysis show good agreement with microscopy. This method efficiently classifies neutrophils, lymphocytes, and eosinophils, but manual screening is still needed for monocytes and immature cells.
Area of Science:
- Veterinary Hematology
- Clinical Pathology
- Automated Cell Analysis
Background:
- Accurate differential leucocyte counts are crucial for diagnosing equine health conditions.
- Manual microscopic analysis of blood smears is time-consuming and can be subjective.
- There is a need for automated, efficient, and reliable methods for equine leucocyte differential counting.
Purpose of the Study:
- To develop and evaluate an automated technique for equine differential leucocyte counts.
- To compare the accuracy of automated volume distribution curve analysis with standard microscopic methods.
- To assess the efficiency and limitations of the automated method for routine veterinary diagnostics.
Main Methods:
- Development of an automated technique using the Coulter Channelyzer for analyzing volume distribution curves of equine leucocytes.
- Evaluation of the technique by comparing its results with standard manual microscopic differential leucocyte counts.
- Analysis of blood samples for both differential and total leucocyte counts at a high throughput rate.
Main Results:
- Good agreement was observed between the automated method and standard microscopic techniques for most leucocyte types.
- The automated system classified an average of 16,000 leucocytes per sample.
- The method demonstrated suitability for precise counting of polymorphonuclear neutrophils, lymphocytes, and eosinophils.
- Blood films still require screening for monocytes and immature cells.
Conclusions:
- Automated analysis of volume distribution curves using the Coulter Channelyzer provides a reliable method for equine differential leucocyte counts.
- The technique significantly enhances efficiency, analyzing 25 samples per hour.
- While effective for neutrophils, lymphocytes, and eosinophils, manual review remains essential for detecting monocytes and immature cells in equine blood samples.
More Related Videos
14:45Enumeration of Major Peripheral Blood Leukocyte Populations for Multicenter Clinical Trials Using a Whole Blood Phenotyping Assay
Published on: September 16, 2012
06:33Identifying Bone Marrow Microenvironmental Populations in Myelodysplastic Syndrome and Acute Myeloid Leukemia
Published on: November 10, 2023