Dose minimization in computed tomography overscanning

D L Parker, V Smith, J H Stanley

    Medical Physics
    |September 1, 1981
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    New Zealand White Rabbits Fed High Cholesterol Diets Develop Morbid Systemic Diseases before Intracranial Atherosclerosis is Detected.

    Journal of veterinary science & medical diagnosis·2026
    Same author

    Nailfold capillaroscopy and organ involvement in systemic sclerosis: a systematic review.

    Best practice & research. Clinical rheumatology·2026
    Same author

    Capillaroscopy in the daily clinic of the pediatric rheumatologist.

    Best practice & research. Clinical rheumatology·2024
    Same author

    Consensus statement on the diagnosis and treatment of sclerosing diseases of the skin, Part 1: Localized scleroderma, systemic sclerosis and overlap syndromes.

    Journal of the European Academy of Dermatology and Venereology : JEADV·2024
    Same author

    Flemish network on rare connective tissue diseases (CTD): patient pathways in systemic sclerosis. First steps taken.

    Acta clinica Belgica·2023
    Same author

    Reply: Artificial intelligence as a door opener for a new era of human reproduction.

    Human reproduction open·2023
    Same journal

    A computer-aided diagnosis tool in prostate cancer patients with biochemical recurrence using 18F-PSMA PET/CT imaging.

    Medical physics·2026
    Same journal

    Investigating the uncertainty of cellular microenvironment parameter estimations via diffusion MRI cytometry.

    Medical physics·2026
    Same journal

    Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

    Medical physics·2026
    Same journal

    Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

    Medical physics·2026
    Same journal

    Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

    Medical physics·2026
    Same journal

    Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

    Medical physics·2026
    See all related articles

    To reduce noise and motion artifacts in computed tomography (CT) scans, overscanning weights should match x-ray flux. Varying x-ray flux during scans optimizes image quality without increasing patient radiation dose.

    Area of Science:

    • Medical Imaging
    • Radiology
    • Image Processing

    Background:

    • Overscanning in computed tomography (CT) involves extending the scan range beyond the region of interest.
    • Balancing noise reduction and radiation dose is crucial in CT imaging.

    Purpose of the Study:

    • To analyze the relationship between noise, radiation dose, and overscanning in CT.
    • To determine optimal overscanning strategies for improved image quality and dose efficiency.

    Main Methods:

    • Reviewing the relationship between noise and dose in CT overscanning.
    • Analyzing overscanning weights for variance reduction and motion artifact suppression.
    • Utilizing computer simulations with a head phantom and moving pin.

    Main Results:

    Related Experiment Videos

    • Maximal variance reduction is achieved when overscanning weights are proportional to x-ray flux.
    • Smoothly varying weights from zero to one optimize motion artifact suppression.
    • Simulations confirmed that variable x-ray flux achieves maximal artifact suppression with no dose increase.

    Conclusions:

    • Optimizing overscanning weights and x-ray flux is essential for high-quality CT imaging.
    • Variable x-ray flux during CT scans can enhance image quality without additional patient dose.
    • This approach offers a method for dose-efficient artifact reduction in CT.