Related Experiment Videos
Factors affecting the labeling efficiency and stability of technetium-99m-labeled glucoheptonate
Abstract:
Factors influencing the labeling efficiency and in vitro stability of 99mTc-labeled glucoheptonate (Tc-GH) were investigated. Using commercially available glucoheptonate kits (New England Nuclear), the following factors were studied: (1) amount of activity added to each kit vial, (2) different brands of 0.9% sodium chloride injection, (3) evaluation of eluates from three commercially available generators, (4) different chromatography systems, (5) storage of the preparation at room temperature and under refrigeration, and (6) labeling with eluates obtained at various times (6, 24, 48, 72, and 96 hours) since previous elution of the generator. Results showed that Tc-GH prepared using 100 mCi of sodium pertechnetate from a Mallinckrodt generator, low-dissolved-oxygen 0.9% sodium chloride injection to make up a constant 5-ml volume, and chromatography with methyl ethyl ketone/sodium chloride on an ITLC-SG system gave the best labeling efficiency over a 24-hour period. Storage temperature and time since previous elution had no effect on labeling efficiency or stability.