Related Experiment Video
Updated: Aug 14, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Thermography in the diagnosis of DVT
Abstract:
161 consecutively admitted medical patients with the clinical suspicion of acute deep venous thrombosis (DVT) were thermographed and phlebographed in order to study the congruence of these methods. The sensitivity of thermography in the detection of DVT was found to be 99%, whereas the specificity was only 49%. The low specificity is explained by the fact that all thermographs suggestive of DVT were classified as pathologic to keep the sensitivity of the method as high as possible. Patients with dilated veins which may closely resemble DVT on thermography may in these cases give false positive results. Of 76 patients with phlebographically verified DVT, 22% became thermographically normal within 22 days, whereas 78% did not normalize within the mean observation time of 31 days. In another part of the study all medical patients (101) who were residing in our wards during a period of a week were screened by means of thermography. From this unselected group 17 patients were found to have thermographs suggestive of DVT. In 5 of these patients no reason for pathological thermography could be found. Thermography is a cheap and highly sensitive screening method for DVT, but findings of false positives caused by older thromboses and dilated veins are not unusual. The frequency of such false positives may be minimized by performing thermography after exercise.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care

