Potentiometric determination of halothane

Polish Journal of Pharmacology and Pharmacy
|January 1, 1981
PubMed

Related Concept Videos

Multiple Halogenation of Methyl Ketones: Haloform Reaction01:28

Multiple Halogenation of Methyl Ketones: Haloform Reaction

A method involving the transformation of methyl ketones to carboxylic acids using excess base and halogen is called the haloform reaction. It begins with the deprotonation of α hydrogen to form an enolate ion which reacts with the electrophilic halogen to give an α-halo ketone. The step continues until all the α protons are substituted to form a trihalomethyl ketone. The resulting molecule is unstable, and in the presence of a hydroxide base, it readily undergoes nucleophilic acyl substitution.
Inductive Effects on Chemical Shift: Overview01:27

Inductive Effects on Chemical Shift: Overview

The protons in unsubstituted alkanes are strongly shielded with chemical shifts below 1.8 ppm. Methine, methylene, and methyl protons appear at approximately 1.7, 1.2 and 0.7 ppm, while the proton signal from methane appears at 0.23 ppm. An electronegative substituent, such as chlorine, withdraws the electron density from the protons, increasing their chemical shift. Progressive substitution of the hydrogens in methane by chlorine shifts the proton signals increasingly downfield, to 3.05 ppm in...
Titration of a Weak Base with a Strong Acid01:20

Titration of a Weak Base with a Strong Acid

The titration curve of a weak base like ammonia with a strong acid like hydrochloric acid is the mirror image of the titration curve of a weak acid with a strong base.
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Potentiometry: Overview01:06

Potentiometry: Overview

Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Stages of General Anesthesia01:22

Stages of General Anesthesia

Various sedation levels offer significant advantages in facilitating procedural interventions for patients undergoing medical or invasive surgical procedures. These levels span from anxiolysis to general anesthesia, providing a spectrum of sedative effects to cater to specific patient needs. Anxiolysis reduces anxiety and is achieved through minimal sedation, enabling patients to remain awake and responsive while feeling more at ease during the procedure. This level can benefit minor...
Inhalational Anesthetics: Overview01:20

Inhalational Anesthetics: Overview

Inhalation anesthetics are drugs that induce general anesthesia upon inhalation. They work by increasing the sensitivity of GABAA receptors or inhibiting NMDA receptors, leading to a decrease in central nervous system activity. The depth of anesthesia can be rapidly adjusted by changing the concentration of the inhaled gas. Some common examples of inhalational anesthetics include volatile liquids like isoflurane, desflurane, sevoflurane and gases like xenon and nitrous oxide. Isoflurane, a...