Related Experiment Video
Updated: Sep 11, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
[The retrograde catheterization of the aortic valve prosthesis. Usefulness and limits (author's transl)]
Insights
Retrograde left ventricle catheterization in patients with aortic valve prostheses can affect hemodynamic measurements. This technique may be useful only for assessing associated mitral valve disease.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Cardiac Surgery
Context:
- Aortic valve prostheses are common in treating aortic valve disease.
- Accurate hemodynamic assessment is crucial for managing cardiac patients.
- Retrograde left ventricle catheterization is a diagnostic procedure.
Purpose:
- To evaluate the impact of retrograde left ventricle catheterization on hemodynamic measurements in patients with aortic valve prostheses.
- To determine the utility of this technique in the presence of prosthetic aortic valves.
Summary:
- Retrograde left ventricle catheterization was performed in 10 patients with aortic valve prostheses.
- Pulmonary wedge pressure increased, while systolic and diastolic aortic pressures decreased.
- Left ventriculography was performed in 5 patients.
- The procedure may compromise accurate hemodynamic measurements.
- It may be suitable for evaluating associated mitral valve disease.
Impact:
- Findings suggest limitations of retrograde left ventricle catheterization for hemodynamic monitoring in patients with aortic valve prostheses.
- The study highlights the need for alternative methods for accurate hemodynamic assessment in this population.
- This information can guide clinical decisions regarding diagnostic procedures in patients with prosthetic valves.
Abstract:
A retrograde catheterization of the left ventricle was performed in 10 patients with aortic valve prosthesis. The pulmonary wedge pressure increased during the procedure (median value 16 mmHg; range 1-33 mmHg). The sistolic aortic pressure (median value 26 mmHg; range 5-60 mmHg) and the diastolic aortic pressure (median value 16 mmHg; range 1-33 mmHg) decreased in all. In 5 patients a left ventriculography was performed. The left ventricle catheterization in patients with aortic valve prosthesis in the experience of the authors may preclude accurate hemodynamic measurements; it may be utilized only for the evaluation of an associated mitral valve disease.
More Related Videos
08:50Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management