Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Uniform Depth Channel Flow: Problem Solving01:18

Uniform Depth Channel Flow: Problem Solving

361
To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...
361
Poiseuille's Law and Reynolds Number01:10

Poiseuille's Law and Reynolds Number

8.8K
Any fluid in a horizontal tube can flow due to pressure differences—fluid flows from high to low pressure. The flow rate (Q) is the ratio of pressure difference and resistance through a horizontal tube. The greater the pressure difference, the higher the flow rate. The flow resistance is expressed as:
8.8K
Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

1.0K
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
1.0K
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

727
A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
727
Design Example: Designing a Residential Plumbing System01:25

Design Example: Designing a Residential Plumbing System

987
The design of residential plumbing systems requires carefully evaluating water demand, flow rates, and pressure dynamics to ensure both efficiency and reliability. The nature of water flow within pipes is defined by its Reynolds number, which classifies flow as either laminar (smooth) or turbulent.
987
Single Pipe Systems01:24

Single Pipe Systems

354
In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
354

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Illicit Substance Use and Harm in Young Adulthood: the Role of Substance Use in Close Relationships and Individual Social Skills.

International journal of mental health and addiction·2025
Same author

Psychosocial predictors of binge-drinking residual harm in adolescence and young adulthood: Findings from the Australian Temperament Project.

Drug and alcohol dependence·2021
Same author

Childhood disadvantage and adolescent socioemotional wellbeing as predictors of future parenting behaviour.

Journal of adolescence·2020
Same author

From adolescence to parenthood: a multi-decade study of preconception mental health problems and postpartum parent-infant bonds.

Social psychiatry and psychiatric epidemiology·2020
Same author

Exploring a causal model in observational cohort data: The role of parents and peers in shaping substance use trajectories.

Addictive behaviors·2020
Same author

A comparison of longitudinal modelling approaches: Alcohol and cannabis use from adolescence to young adulthood.

Drug and alcohol dependence·2019

Related Experiment Video

Updated: Dec 19, 2025

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
07:15

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure

Published on: April 25, 2025

854

The flow rate nomogram: II. Clinical correlation

M B Siroky, C A Olsson, R J Krane

    The Journal of Urology
    |February 1, 1980
    PubMed
    Summary
    This summary is machine-generated.

    This study shows that uroflowmetry effectively diagnoses urinary outflow obstruction. Post-operative uroflowmetry confirms successful treatment, with significant improvements in peak flow rate for patients.

    More Related Videos

    Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture
    10:00

    Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture

    Published on: July 20, 2022

    2.7K
    Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
    10:02

    Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow

    Published on: April 29, 2011

    16.7K

    Related Experiment Videos

    Last Updated: Dec 19, 2025

    Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
    07:15

    Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure

    Published on: April 25, 2025

    854
    Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture
    10:00

    Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture

    Published on: July 20, 2022

    2.7K
    Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
    10:02

    Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow

    Published on: April 29, 2011

    16.7K

    Area of Science:

    • Urology
    • Medical Diagnostics

    Background:

    • Urinary outflow obstruction is a common condition affecting many individuals.
    • Accurate diagnosis and monitoring are crucial for effective patient management.

    Purpose of the Study:

    • To evaluate the diagnostic utility of uroflowmetry in patients with urinary outflow obstruction.
    • To assess the effectiveness of surgical intervention for outflow obstruction using uroflowmetry.

    Main Methods:

    • Uroflowmetry was performed on 53 patients with clinically evident outflow obstruction.
    • 32 patients were tested before and after surgical treatment.
    • A flow rate nomogram was used to interpret results against normal population values.

    Main Results:

    • 98% of obstructed patients showed maximum flow measurements below -2 standard deviations from normal values.
    • Post-surgery, all patients' uroflowmetry values normalized.
    • Peak flow rate increased by an average of 2.7 standard deviations after surgery.

    Conclusions:

    • Uroflowmetry reliably differentiates between normal and obstructed urinary flow.
    • The flow rate nomogram is a valuable tool for diagnosing and monitoring urinary outflow obstruction.