Related Experiment Video
Updated: Jul 28, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
New declotting catheters for arterio-venous shunts
Insights
New stainless steel instruments effectively declot arteriovenous (A-V) shunts, reducing the need for surgical revisions and preserving vascular access for hemodialysis patients.
Area of Science:
- Vascular Surgery
- Nephrology
- Biomedical Engineering
Background:
- Clotting in arteriovenous (A-V) shunts is a significant complication for hemodialysis patients.
- Existing declotting methods like balloon embolectomy are often unsuccessful, leading to repeat surgical revisions.
- Frequent shunt revisions compromise vascular access sites, impacting dialysis adequacy.
Purpose of the Study:
- To introduce novel stainless steel instruments designed for declotting A-V shunts.
- To evaluate the efficacy of these new instruments in removing vascular obstructions.
- To reduce the frequency of surgical shunt revisions and prolong shunt lifespan.
Main Methods:
- Development and application of three specific stainless steel instruments: Expanding Mesh, Helix, and Rotating Cutter.
- Targeting common obstruction sites: shunt tips and anastomosis.
- Utilizing instruments to dislodge organized clots, cut fibrin flaps, and enlarge vessel lumens.
Main Results:
- The novel instruments successfully removed vascular obstructions in A-V shunts.
- Successful declotting occurred at critical sites, including shunt tips and anastomosis.
- Prolonged shunt lifespan was achieved, leading to a decrease in necessary surgical revisions.
Conclusions:
- New stainless steel instruments offer an effective solution for declotting A-V shunts.
- These devices can successfully manage common obstruction sites, improving shunt patency.
- The use of these instruments reduces the need for surgical intervention, preserving vascular access for hemodialysis.
Abstract:
Clotting is a serious problem in patients with A-V shunts. Balloon Embolectomy catheters or irrigating devices are frequently unsuccessful in declotting shunts, resulting in surgical revision of the shunt. Frequent surgical revisions reduce sites of vascular access, making it difficult to perform adequate hemodialysis. New instruments, constructed mainly of stainless steel, have been devised and used to declot A-V shunts. The instruments have been devised for specific purposes and labeled as follows: (1) Explanding Mesh, (2) Helix and (3) Rotating Cutter. These instruments will dislodge and remove organized clots, snare and cut fibrin "flaps", open and enlarge the vessel lumens. They have been used successfully in removing vascular obstructions adjacent to the vessel tips of the shunt or at the site of anastamosis of the shunt and vessel. These are the most common sites of obstruction. By prolonging shunt life we have been able to decrease the number of shunt revisions.
More Related Videos
Related Concept Videos
Cardiac Catheterization IV: Nursing Management