Hearing threshold for a decaying oscillatory waveform

H P Wit

    The Journal of Auditory Research
    |January 1, 1978
    PubMed
    Summary
    This summary is machine-generated.

    This study compared hearing thresholds for damped wave signals versus pure-tone signals. Pure-tone signals were found to have lower hearing thresholds, with differences ranging from 8.6 to 19.6 dB.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Asymmetric vestibular evoked myogenic potentials in unilateral Menière patients.

    European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery·2010
    Same author

    The effect of changes in perilymphatic K+ on the vestibular evoked potential in the guinea pig.

    European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery·2010
    Same author

    Three-dimensional reconstruction of the pigeon inner ear.

    Journal of vestibular research : equilibrium & orientation·2009
    Same author

    Acute endolymphatic hydrops has no direct effect on the vestibular evoked potential in the guinea pig.

    Journal of vestibular research : equilibrium & orientation·2009
    Same author

    A Bast-like valve in the pigeon?

    European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery·2009
    Same author

    Three-dimensional reconstruction of the guinea pig inner ear, comparison of OPFOS and light microscopy, applications of 3D reconstruction.

    Journal of microscopy·2009
    Same journal

    Conditions under which the Haas precedence effect may or may not occur.

    The Journal of auditory research·1987
    Same journal

    Fabrication of a new headset for air- and bone-conduction audiometry.

    The Journal of auditory research·1987
    Same journal

    High-frequency Bekesy audiometry: VI. Pulsed vs. continuous signals.

    The Journal of auditory research·1987
    Same journal

    Effect of warble-tone frequency deviation on threshold measurement in cases with sloping audiometric configurations.

    The Journal of auditory research·1987
    Same journal

    Speech reception thresholds for digits.

    The Journal of auditory research·1987
    Same journal

    Auditory localization in a free field using discrimination procedures.

    The Journal of auditory research·1987
    See all related articles

    Area of Science:

    • Audiology
    • Acoustics
    • Psychoacoustics

    Background:

    • Understanding auditory perception is crucial for diagnosing hearing loss.
    • Damped wave signals and pure-tone signals represent different acoustic stimuli.
    • Comparing hearing thresholds for these signal types can reveal differences in auditory processing.

    Purpose of the Study:

    • To measure and compare hearing thresholds for damped wave signals and pure-tone signals.
    • To quantify the difference in hearing sensitivity between these two signal types across various frequencies.

    Main Methods:

    • Hearing thresholds were measured for a damped wave signal at 8 frequencies (0.35–4 kHz).
    • These thresholds were compared to hearing thresholds for pure-tone signals at the same frequencies.

    Related Experiment Videos

  • Hearing threshold for the damped wave signal was expressed in peak decibels (dB) re 20 micropascals (µPa).
  • Main Results:

    • Hearing thresholds for pure-tone signals were consistently lower than for damped wave signals.
    • The difference in hearing threshold levels ranged irregularly from 8.6 to 19.6 dB.
    • This difference favored pure-tone signals, indicating greater audibility.

    Conclusions:

    • Pure-tone signals are perceived with greater sensitivity than damped wave signals within the tested frequency range.
    • The observed differences in hearing thresholds can be modeled using a simple mathematical approach.
    • These findings contribute to a better understanding of auditory signal processing.