Related Experiment Video
Updated: Jul 30, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Backward extrapolation of VO2max values from the O2 recovery curve
Abstract:
The purpose of this study was to validate a method for measuring Vo2max in field conditions. In order to do so, Vo2max obtained by backward extrapolation of the O2 recovery curve at time zero of recovery (BE), was compared to the Vo2max measured directly at the end of a continuous multistage test (Exercise). The optimal way to determine Vo2max was by using a single component exponential least-squares regression on the first three or four 20 x recovery values. When a three-way valve was used to collect expired air immediately at the start of recovery (n=20), BE Vo2max (X- +/- SD=56.5 +/- 7.4 ML KG-1 MIN-1) WAS NOT SIGNIFICANTLY DIFFERENT FROM Exercise Vo2max (56.1 +/- 7.6). When subjects (n=16) connected themselves to another breathing valve immediately at the end of the test to simulate field conditions BE and Exercise Vo2max were similar (63.9 +/- 6.7 and 63.1 +/- 7.0, respectively) as long as a 3 s correction was made for the delay caused by this procedure. BE and Exercise Vo2max were 59.8 +/- 8 and 59.2 +/- 8.1 for the 36 subjects; the Pearson's correlation coefficient was 0.92. BE Vo2max measured on 11 additional runners tested on a track (62.6 +/- 13) yielded similar results as Exercise Vo2max measured on the treadmill using the same protocol (61.2 +/- 13.3). The backward extrapolation method appears to be valid to measure Vo2max when the air collecting equipment might otherwise be cumubersome during actual sport and/or laboratory conditions.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Related Concept Videos
Lung Capacity
Respiratory Volumes and Capacities I
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...