A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Assessment of the severity of aortic stenosis from the carotid pulse tracing
Insights
Carotid pulse tracings can distinguish aortic stenosis from normal heart function. However, these external pulse recordings cannot determine the severity of aortic stenosis in patients.
Area of Science:
- Cardiology
- Biomedical Engineering
- Diagnostic Imaging
Background:
- Valvular aortic stenosis is a significant cardiovascular condition requiring accurate severity assessment.
- External carotid pulse tracing offers a non-invasive method for cardiovascular evaluation.
- Understanding the relationship between carotid pulse morphology and aortic stenosis severity is crucial for clinical practice.
Purpose of the Study:
- To investigate the utility of externally recorded carotid pulse tracing in assessing valvular aortic stenosis.
- To correlate carotid pulse waveform indices with the severity of aortic stenosis.
- To compare carotid pulse characteristics between patients with aortic stenosis and healthy controls.
Main Methods:
- Analysis of carotid pulse tracings from 33 patients with valvular aortic stenosis and 10 normal controls.
- Measurement of initial upstroke time (IUT) and rate of rise of the carotid pulse.
- Correlation of pulse indices with hemodynamic parameters including mean velocity of circumferential fiber shortening (mVcf), cardiac index, systemic vascular resistance, stroke volume, and ejection fraction.
Main Results:
- Patients with aortic stenosis exhibited significantly higher IUT and left ventricular ejection time index, and a slower rate of carotid pulse rise compared to controls.
- Carotid pulse indices (IUT and rate of rise) showed good correlation with mean velocity of circumferential fiber shortening (mVcf).
- Severity of aortic stenosis, assessed by valve area and pressure gradient, could not be predicted from the analyzed carotid pulse indices.
Conclusions:
- External carotid pulse tracings can effectively differentiate patients with aortic stenosis from normal individuals.
- The analyzed indices of the external carotid pulse do not provide a reliable measure for quantifying the severity of aortic stenosis.
- Further research may be needed to explore other non-invasive methods for severity assessment in aortic stenosis.
Abstract:
The morphology of the externally recorded carotid pulse tracing was studied in 33 patients with valvular aortic stenosis for indices of severity. Comparisons were made with 10 normal controls. In aortic stenosis, initial upstroke time (IUT) of the carotid pulse, and left ventricular ejection time index were significantly higher and the rate of rise of the carotid pulse was slower than in the control group. Severity of stenosis (calculated valve area and mean pressure gradient) could not be predicted, however, from any of these indices. The IUT of the carotid pulse did correlate well with mean velocity of circumferential fiber shortening (mVcf) (r=-0.72). The rate of rise of the carotid pulse had also a correlation with mVcf(r=0.66). However, other commonly used hemodynamic indices (cardiac index, systemic vascular resistance, stroke volume, and ejection fraction) did not have a good correlation with IUT and rate of rise of the carotid pulse. These results suggest that we are able to separate by carotid pulse tracings aortic stenosis from normal subjects, but we cannot say what is the degree of severity of aortic stenosis from analysis of the external carotid pulse recording.
More Related Videos
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm II: Clinical Manifestations and Diagnostic Studies