In vivo comparison of triamcinolone and beclomethasone inhalation delivery systems
Abstract:
The efficiencies of two metered dose delivery systems designed for oral inhalation of glucocorticoids (triamcinolone acetonide and beclomethasone dipropionate) were compared in an open-labeled, randomized, crossover fashion in 18 asthmatic patients. Measurements were made of the mean amount of glucocorticoid released per actuation at the aerosol valve of each delivery system, the mean amount in a post-dose gargle and saliva specimen and the mean amount that remained in the oral adapter after use of each system. Retention in the oropharyngeal cavity was 7.3% and 40.3% of delivered dose for the triamcinolone acetonide and beclomethasone dipropionate systems (P < 0.001). The amount of glucocorticoid potentially available to the bronchial airways was 92.7% of the delivered dose for the triamcinolone acetonide and 59.7% for the beclomethasone dipropionate system.