Pattern of accident distribution in the telecommunications industry
British Journal of Industrial Medicine
|May 1, 1980
Summary
Telecommunication engineers experience significant back injuries from handling accidents and falls. Specific occupations and age groups (31-48 years) face higher accident risks, influenced by seasonality and experience.
Area of Science:
- Occupational Health
- Ergonomics
- Telecommunication Industry Safety
Background:
- Accidents in the telecommunication industry pose a risk to engineers.
- Back injuries are a common consequence of workplace incidents.
- Understanding risk factors is crucial for injury prevention.
Purpose of the Study:
- To analyze accident records in the telecommunication industry.
- To identify the primary causes and types of accidents, particularly those causing back injuries.
- To determine the influence of demographic and occupational factors on accident rates.
Main Methods:
- Review of accident records for approximately 100,000 engineers over 12 months.
- Categorization of accidents by type (handling, falls) and injury (back injuries).
- Statistical comparison of accident incidence with population demographics (age, occupation).
Main Results:
- 25% of accidents causing over three days of sick leave resulted in back injuries.
- Handling accidents and falls comprised 65% of major accidents; handling alone caused 65% of back injuries.
- Certain occupations (33% of engineers) experienced 70% of major accidents; peak accident age was 31-48 years.
Conclusions:
- Handling activities and falls are major contributors to workplace accidents and back injuries among telecommunication engineers.
- Specific occupations and age demographics (31-48 years) are at higher risk.
- Accident risk is further modulated by factors such as time of year and worker experience.
Related Concept Videos
Determination of Expected Frequency
Suppose one wants to test independence between the two variables of a contingency table. The values in the table constitute the observed frequencies of the dataset. But how does one determine the expected frequency of the dataset? One of the important assumptions is that the two variables are independent, which means the variables do not influence each other. For independent variables, the statistical probability of any event involving both variables is calculated by multiplying the individual...
Design Example
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
Primary Distribution
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
Distribution Reliability and Automation
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
Fault Types
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
Pilot and Numeric Relaying
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying: