Technique for insertion of the superior loop of the Shearing-style posterior chamber lens
Abstract:
An angulated lens guide and iris hook are described for inserting the superior loop of a Shearing-style lens implant.
Related Concept Videos
Articles linked to this work by shared authors, journal, and citation graph.
Pseudomonas aeruginosa endophthalmitis caused by contamination of the internal fluid pathways of a phacoemulsifier.
Journal of cataract and refractive surgery·1999
Evaluation of the biocompatibility and fixation of a new silicone intraocular lens in the feline model.
Journal of cataract and refractive surgery·1989
Spontaneous enlargement of neodymium:YAG posterior capsulotomy in aphakic and pseudophakic patients.
Journal of cataract and refractive surgery·1988
Cataract extraction in eyes with congenital colobomata.
Journal of cataract and refractive surgery·1987
The 1985 Binkhorst lecture. Ultraviolet-absorbing chromophores: chemical and ultraviolet transmission characteristics.
Journal of cataract and refractive surgery·1986
Bacterial recovery from automated cataract surgical equipment.
Journal of cataract and refractive surgery·1986
Preparation of 2% hydroxypropyl methylcellulose for viscous surgery.
Journal - American Intra-Ocular Implant Society·1985
Cleaning an in situ intraocular lens using a disposable hypodermic needle.
Journal - American Intra-Ocular Implant Society·1985
The effects of hard contact lenses on intraocular lens calculations.
Journal - American Intra-Ocular Implant Society·1985
Surface reaction on a posterior chamber lens seven days after implantation.
Journal - American Intra-Ocular Implant Society·1985
Corneal ulceration following cataract surgery in patients with rheumatoid arthritis.
Journal - American Intra-Ocular Implant Society·1985
The Haag-Streit Lotmar Visometer for determining macular potential prior to cataract surgery.
Journal - American Intra-Ocular Implant Society·1985
Development and Clinical Evaluation of an Anterior Chamber Angle-Based Lens Sizing Method for Implantable Collamer Lens Surgery.
Clinical ophthalmology (Auckland, N.Z.)·2026
What does it take to grasp a tool? A fine-grained multiple-case analysis of hand-tool and tool-object interaction errors in apraxia.
Cortex; a journal devoted to the study of the nervous system and behavior·2026
A Smartphone-based Gyroscopic Method of Pedicle Screw Fixation-A Pilot Study and Technical Note.
Asian journal of neurosurgery·2026
Drivers and barriers of AI tool adoption in Jordanian SMEs: a qualitative TOE-based study.
Frontiers in artificial intelligence·2026
SMartini: automated small molecule parametrization for Martini 3 force field.
bioRxiv : the preprint server for biology·2026