Assessment of Vascular Function in Patients With Chronic Kidney Disease
Published on: June 16, 2014
[Assessment of arterial hypertension associated with renal transplantation using Doppler ultrasonography]
F J Burgos Revilla1, L Orofino Ascunce, T Mayayo Dehesa
1Servicio de Urología, Hospital Ramón y Cajal, Universidad de Alcalá de Henares, Madrid, España.
Objectives:
The incidence of arterial hypertension post-renal transplantation has been reported to be 48.6%. The present study investigated the usefulness of echo Doppler in detecting renal artery stenosis and the effects of arterial pressure control and hypotensive agents on the vascular resistance of the renal graft.
Methods:
A total of 234 echo Doppler studies were done in 110 patients. The pulsatility index (PI), resistance index (RI), acceleration and mean velocity (MV), maximum systolic (SVMX) and minimum diastolic (DVMN) velocities of the external iliac, renal, segmental, interlobar and arcuate arteries were determined.
Results:
In the stenotic segment, an elevation of SVMX was observed, followed by turbulent flow in the post-stenotic segment in 73% of the cases with arterial stenosis. The hypertensive patients had a higher external iliac artery RI than the normotensives. The beta-blockers reduced the RI in large vessels (external iliac), the vasodilators in medium-sized extraparenchymal vessels (segmental) and the calcium antagonists changed the PI in the smaller caliber intraparenchymal vessels (interlobar and arcuate).
Conclusions:
Evaluation by echo Doppler is the first diagnostic approach in patients suspected as having arterial stenosis of the renal graft. It permits evaluating blood flow changes from hypertension and hypotensive agents.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Hypertension III: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies II: Ultrasonography