Related Experiment Videos
[Pulmonary atresia with intact ventricular septum. Valvar perforation by radiofrequency]
V F Fontes1, C A Esteves, S L Braga
1Instituto Dante Pazzanese de Cardiologia, São Paulo.
Arquivos Brasileiros De Cardiologia
|March 1, 1995
Abstract:
Six days old neonate with pulmonary atresia and intact ventricular septum is reported in which a communication was established between the right ventricle and the pulmonary artery. The membraneous atresia was perforated with a special radiofrequency catheter 2F connected to a Hat 200S radiofrequency generator (Osypka). The energy necessary to perforation was 15W. After perforation of the atresia, balloon dilation was performed (balloon diameter: 2, 3, 4mm of coronary angioplasty and 5, 8mm Penta Medi-tech). The valve was completely opened giving the continuity between right ventricle and pulmonary artery.