Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Peripheral contrast sensitivity for dynamic sinusoidal gratings in early glaucoma

B L Lundh1, E Gottvall

  • 1Department of Ophthalmology, University Hospital, Linköping, Sweden.

Acta Ophthalmologica Scandinavica
|June 1, 1995
PubMed
Summary

Early glaucoma patients without visual field defects showed elevated contrast thresholds, indicating reduced contrast sensitivity. However, this method has limited value for individual glaucoma detection due to overlapping results with controls.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Bilateral same day phacoemulsification: 220 cases retrospectively reviewed.

The British journal of ophthalmology·2003
Same author

Colour contrast sensitivity in cataract and pseudophakia.

Acta ophthalmologica Scandinavica·2000
Same author

Changes in the direct-current electroretinogram of albino rabbits during prolonged intermittent recording.

European journal of ophthalmology·1997
Same author

Effects of prolonged uniocular dark adaptation on the direct-current electroretinogram of pigmented and albino rabbits.

Documenta ophthalmologica. Advances in ophthalmology·1995
Same author

Normal human contrast sensitivity for static and dynamic sinusoidal gratings. A comparison between two automated threshold determination designs.

Acta ophthalmologica·1994
Same author

The c-wave of the direct-current electroretinogram and the standing potential of the albino rabbit eye in response to repeated series of light stimuli with different interstimulus intervals.

Documenta ophthalmologica. Advances in ophthalmology·1993

Area of Science:

  • Ophthalmology
  • Visual Neuroscience
  • Medical Imaging

Background:

  • Glaucoma is a leading cause of irreversible blindness.
  • Early detection of glaucoma is crucial for preserving vision.
  • Contrast sensitivity testing may reveal subclinical visual dysfunction.

Purpose of the Study:

  • To investigate contrast sensitivity in early glaucoma patients without visual field defects.
  • To evaluate the utility of automated contrast threshold testing for glaucoma detection.

Main Methods:

  • Automated contrast thresholds were measured using dynamic, phase-shifted sinusoidal gratings.
  • Testing was performed in a 5-degree circular field at six visual field positions in 16 early glaucoma patients and 16 controls.
  • Three spatial frequencies (0.5, 1.0, 2.0 cycles per degree) were used.

Related Experiment Videos

Main Results:

  • Glaucoma patients exhibited significantly elevated contrast thresholds across tested spatial frequencies compared to controls.
  • Contrast sensitivity loss was observed in all tested visual field positions, with greater deficits in the lower hemi-field.
  • Threshold elevations did not correlate with glaucoma type, intraocular pressure, visual acuity, or therapy.

Conclusions:

  • Early glaucoma, even without apparent visual field defects, is associated with reduced contrast sensitivity.
  • Automated contrast threshold testing can detect visual dysfunction in early glaucoma.
  • Significant overlap in threshold values between glaucoma patients and controls limits its value for individual glaucoma detection.