Cardiovascular effects of moderate normovolaemic haemodilution during enflurane-nitrous oxide anaesthesia in man
P Van der Linden1, M Wathieu, E Gilbart
1Department of Anaesthesiology, Erasme University Hospital, Free University of Brussels, Belgium.
Abstract:
The cardiovascular effects of mild normovolaemic haemodilution during enflurane-nitrous oxide anaesthesia were studied in 20 patients with normal cardiac function before, during and after total hip replacement. After induction of anaesthesia, patients were randomly allocated to one control group (C), or one haemodiluted group (H) where Hct was decreased to 30% by replacement of blood volume by an identical volume of hydroxyethyl starch 200/05. Each patient was monitored with a pulmonary artery catheter allowing the measurement of right ventricular ejection fraction. During haemodilution, stroke index and right ventricular end-diastolic volume index increased from 33.1 +/- 7.9 to 39.3 +/- 7.1 ml.M-2 and from 73.8 +/- 20.3 to 94.9 +/- 18.5 ml.M-2 respectively (mean +/- s.d., both P < 0.05). However, heart rate decreased so that cardiac index did not change. O2 delivery decreased significantly (from 389 +/- 70 to 311 +/- 63 ml.min-1.m-2; P < 0.05), but was not different to the control group. O2 consumption was maintained by an increase in O2 extraction. During the surgical procedure, cardiac index was higher in the haemodiluted group than in the control group, so that O2 delivery was similar in the two groups. O2 consumption tended to be greater in the haemodiluted group. In patients with normal cardiac function, enflurane-nitrous oxide anesthesia could alter the normal physiologic response to mild normovolaemic haemodilution.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Parenteral Anesthetics: Overview
Inhalational Anesthetics: Overview