Related Experiment Video
Updated: Aug 16, 2026

Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Insonation and impedance analysis in graft surveillance
K R Woodburn1, A Murtagh, P Breslin
1Unit for Peripheral Vascular Surgery, Royal Infirmary, Glasgow, UK.
Abstract:
Seventy consecutive patients with infrainguinal bypass grafts entered a 1-year graft surveillance programme involving colour duplex scanning, direct graft insonation and computer-assisted impedance analysis. Graft patients with a positive duplex scan, high frequencies on graft insonation or an impedance value above 0.50 subsequently underwent arteriography. Sixteen patients were excluded before the initial surveillance visit. The 54 remaining patients with grafts (30 vein, 24 synthetic) underwent a total of 137 surveillance visits, with 21 grafts confirmed to be 'at risk'. The sensitivity of an impedance value above 0.55 in identifying these grafts was 86 per cent, rising to 95 per cent when combined with graft insonation. Duplex scanning did not identify any abnormalities in 11 grafts that were either shown by arteriography to be 'at risk' or occluded before arteriography. Impedance measurement and graft insonation are simple screening techniques with a high sensitivity (when combined), which identify 'at risk' infrainguinal grafts. Positive graft insonation or an impedance value over 0.55 will identify all 'at risk' vein grafts while minimizing the number of unnecessary arteriograms.