The significance of sieve-retention to the filter validation process
1Capitola Consulting Company, Arlington, Virginia, USA.
Abstract:
Current efforts at filter validation involve the need to test under "worst case conditions" the bacterial retentive action of filters utilizing the very drug being processed. These concerns recognize that the adsorptive retentions of organisms vary in their efficiencies, depending upon the filtration conditions and the presence or absence of surfactant. The sieve retention of organisms is independent of such conditions, deriving solely from considerations of organism-size, pore-size relationships. Flow-decay studies, can serve to differentiate between filter actions based on sieve-retentions and adsorptive-retentions. A filter's dependence solely upon sieving effects is demonstrable. What is involved is a plotting of flow rates as a function of time in accordance with established mathematical equations. Appropriate plots would indicate the exclusive sieve retention of organisms, a condition of absolute filter reliability deriving from organism-pore size relationships. The clear demonstration by a filter company that its sterilizing filter retains organisms solely by the sieve retention mechanism would suffice to validate that filter for all pharmaceutical filtrations, eliminating the need for individual user validations. The advantage of this mode of filter validation, one based on structurally-inherent filter pore architecture, is that pharmaceutical manufacturers would be free from the need to validate a given filter for each and every pharmaceutical preparation. This would also simplify the FDA's confirmation of filter validation, since a single inspection of the filter manufacturer's records would suffice for all the filter's users.
More Related Videos
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
10:14An Efficient Sieving Method to Isolate Intact Glomeruli from Adult Rat Kidney
Published on: November 1, 2018
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Filtration
Dialysis
Data Validation
Key parameters for method validation include:
Sieve Analysis and Grading Curves