Nitric oxide administration using constant-flow ventilation
J W Skimming1, S Cassin, P B Blanch
1Department of Physiology, University of Florida College of Medicine, Gainesville 32610, USA.
Abstract:
Nitric oxide (NO) gas is known as both a vasodilator and a toxin. It can react with oxygen to form compounds more toxic than itself, such as nitrogen dioxide (NO2). The reactions are time dependent; thus, infusing NO into breathing circuits as close to ventilated subjects as possible may help minimize toxic byproduct exposure. Unfortunately, flow rates commonly used with mechanical ventilation favor laminar gas flow (streaming) within the breathing circuits. Streaming could delay mixing of NO with other inhaled gases. This mixing delay may interfere with accurate monitoring and/or delivery of NO. We tested the hypothesis that streaming of NO infused by constant flow into the inspiratory limb of a constant-flow mechanical ventilation system can lead to NO concentration delivery estimate errors. We then compared the NO2 concentrations at the ventilator Y-piece with three different NO mixing methods: blending the gases before they reach the breathing circuit inspiratory limb, infusing NO directly into the breathing circuit inspiratory limb far enough from the Y-piece to ensure thorough mixing, and infusing NO directly into the breathing circuit inspiratory limb immediately before the gases reach an in-line mixing device placed close to the Y-piece. Our results indicate that streaming can lead to NO concentration delivery estimate errors and that these errors can be characterized by measuring NO concentration variations across the inspiratory tubing's luminal diameter. NO2 concentration measured at the ventilator Y-piece were dependent on NO concentrations (p < 0.0001), NO delivery methods (p < 0.0001), and interactions between NO concentrations and NO delivery methods (p < 0.0001). We conclude that gas streaming and toxic byproduct exposure should be considered together when choosing an NO delivery method.
More Related Videos
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Related Concept Videos
Nitric Oxide Signaling Pathway
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)