Related Experiment Videos
Magnetic resonance imaging for diagnosis of digital flexor tendon rupture after primary repair
J H Calandruccio1, J B Steichen
1Campbell Clinic Department of Orthopaedic Surgery, University of Tennessee, Memphis, USA.
Journal of Hand Surgery (Edinburgh, Scotland)
|June 1, 1995
Abstract:
Because the clinical diagnosis of rupture of a digital flexor tendon was uncertain 10 days after primary repair, magnetic resonance imaging was used for evaluation, correlating precisely with the surgical pathology. This non-invasive tool can be very helpful in the early post-operative period when active flexion is not possible to aid in the clinical diagnosis of tendon rupture.