Suffocation from use of modified gas mask

J D Howard1

  • 1Department of Pathology, College of Medicine, University of Arizona, Tucson, USA.

The American Journal of Forensic Medicine and Pathology
|June 1, 1995
PubMed
Summary

Improperly modified gas masks, like those with plastic bags, can lead to suffocation. This case highlights the fatal risks of using respiratory devices for volatile substance inhalation.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

New method for assessing hand disinfection shows that pre-operative alcohol/chlorhexidine rub is as effective as a traditional surgical scrub.

The Journal of hospital infection·2014
Same author

A 3'-UTR KRAS-variant is associated with cisplatin resistance in patients with recurrent and/or metastatic head and neck squamous cell carcinoma.

Annals of oncology : official journal of the European Society for Medical Oncology·2014
Same author

Anaphylaxis and other adverse reactions to blue dyes: a case series.

Anaesthesia and intensive care·2011
Same author

A simple FISH assay for the detection of 3q26 rearrangements in myeloid malignancy.

Leukemia·2007
Same author

Application of growth factor stimulants improves cytogenetic analysis of chronic myeloproliferative disorder patients without alteration to cell lineage or clonality.

Cancer genetics and cytogenetics·2007
Same author

The credibility of a source influences the rate of unconscious plagiarism.

Memory (Hove, England)·2000

Area of Science:

  • Toxicology
  • Forensic Pathology
  • Respiratory Medicine

Background:

  • Gas masks and plastic bags are sometimes misused for volatile substance inhalation.
  • This practice carries inherent risks of respiratory compromise.

Observation:

  • A case of suffocation was documented.
  • The individual used a gas mask modified with a plastic bag.
  • Evidence of halothane inhalation was present.

Findings:

  • The modification of the gas mask with a plastic bag led to suffocation.
  • Halothane inhalation was a contributing factor in the fatality.

Implications:

  • Improper use or modification of respiratory protection devices can be fatal.
  • This case underscores the dangers associated with volatile substance abuse and non-standard inhalation methods.