Related Experiment Video
Updated: Aug 14, 2026

Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Maxima and Bain breathing systems compared in controlled ventilation
1Department of Anaesthesiology, Tygerberg Hospital, University of Stellenbosch Medical School, South Africa.
Abstract:
The Maxima is a new universal breathing system, which, despite its being valveless, functions with near maximal efficiency in spontaneous and controlled ventilation. It was compared to the Bain system in controlled ventilation by adjusting fresh gas flows (VF) to achieve an end-tidal CO2 of 5% in 40 patients aged from one to seventy-six years. They received a combined regional and general anaesthetic technique. The overall VF requirement of the Maxima system was: weight in kg x 35 ml.min-1.kg-1 + 1160 ml.min-1; the Bain system required VF of: weight in kg x 42 ml.min-1.kg-1 + 2070 ml.min-1. The mean VF requirement for the Bain system was greater by 45%. Of these forty patients, the results from the twenty-four adult patients weighing 50 kg or more gave the respective VF requirements for the Maxima and Bain systems of 52 and 71 ml.min-1.kg-1. In a separate study using twenty-nine patients, the fractional utilization of fresh gas (FU) (or VAe/VF where VAe = effective alveolar ventilation) in the Maxima and Bain systems was shown to be 0.94 and 0.71 respectively.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...