Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
Comparison in spontaneous ventilation of the Maxima with the Humphrey ADE breathing system and between four methods
1Department of Anaesthesiology, Tygerberg Hospital, University of Stellenbosch Medical School, South Africa.
Abstract:
An enclosed efferent, afferent reservoir breathing system (Maxima, Life Air Pty Ltd), being valveless, was compared to a simple afferent reservoir system (Humphrey ADE, A mode), having a valve, by assessing fresh gas flow (VF) requirements, with respect to ventilation (VE), that prevents rebreathing in volunteers, awake and breathing spontaneously. The results are recorded in terms of the quotient VF/VE associated with the onset of rebreathing. At the same time four clinical methods for assessing rebreathing were evaluated from the perspective of suitability for practical application during anaesthesia. No significant difference was found in the VF requirements between the ADE and Maxima breathing systems with respective values obtained for the quotient VF/VE of 0.80 and 0.77. Our findings showed that the method of sampling carbon dioxide (CO2) at the outflow of the efferent limb of the patient connector (eliminated CO2 method) in both afferent reservoir systems provided the highest flow rate and most reliable indication for detecting potential or actual rebreathing, when attempting to minimize VF. It provides no additional deadspace or resistance to gas flow, and has the advantage of being the only qualitative method that is reliable for the purpose of detecting the onset of rebreathing.
More Related Videos
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities I
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Respiratory Volumes and Capacities
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...