A comparison of surface doses for two immobilizing systems

M W Johnson1, M A Griggs, S C Sharma

  • 1Department of Radiation Oncology, E. W. Sparrow Hospital, Lansing, MI 48909.

Medical Dosimetry : Official Journal of the American Association of Medical Dosimetrists
|January 1, 1995
PubMed
Summary

Alpha Cradle and VacFix immobilizing systems improve treatment repositioning. CT scans revealed density variations, impacting radiation dose delivery and patient surface dose, crucial for radiotherapy accuracy.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Phase transitions in a programmable quantum spin glass simulator.

Science (New York, N.Y.)·2018
Same author

Psychedelics as Medicines: An Emerging New Paradigm.

Clinical pharmacology and therapeutics·2016
Same author

Oviposition preference of the diamondback moth (Plutella xylostelld) unaffected by the presence of conspecific eggs orBacillus thuringiensis.

Journal of chemical ecology·2013
Same author

Thermally assisted quantum annealing of a 16-qubit problem.

Nature communications·2013
Same author

Traction-induced foveal damage predisposes eyes with pre-existing posterior vitreous detachment to idiopathic macular hole formation.

Eye (London, England)·2012
Same author

Quantum annealing with manufactured spins.

Nature·2011

Area of Science:

  • Medical Physics
  • Radiotherapy Technology
  • Radiation Oncology

Background:

  • Accurate patient positioning is vital for reproducible radiotherapy treatments.
  • Immobilization devices like Alpha Cradle and VacFix conform to patients, enhancing daily setup consistency.
  • Potential beam modification by these systems can alter target dose and increase surface dose.

Purpose of the Study:

  • To evaluate the dosimetric impact of Alpha Cradle and VacFix immobilization systems.
  • To compare the relative densities of these systems using CT scans.
  • To assess the effect on patient surface dose from different radiation sources.

Main Methods:

  • CT scans were performed on Alpha Cradle and VacFix systems.
  • Relative densities were calculated and compared to air.

Related Experiment Videos

  • Surface dose measurements were taken using Cobalt-60 and dual photon linear accelerator beams.
  • Main Results:

    • CT scans provided relative density data for both immobilization systems.
    • Calculated densities indicate potential for radiation beam modification.
    • Surface dose data highlights variations depending on the immobilization system and radiation source.

    Conclusions:

    • Immobilization systems can influence radiation dose distribution.
    • Understanding material densities is key to predicting dosimetric effects.
    • Further investigation is needed to optimize immobilization techniques for accurate radiotherapy delivery.