Background:
The appearance of cardiac proteins in blood is the most specific and sensitive indicator of acute myocardial cell necrosis. The measurement of cardiac markers, however, is time consuming and requires sophisticated equipment. To facilitate the biochemical detection for acute myocardial cell necrosis, a whole-blood rapid assay device for cardiac troponin T detection was developed that provides a test result within 20 minutes.
Methods And Results:
Monoclonal antibody M7 is labeled with gold particles, and antibody 1B10 is labeled with biotin. Both antibodies, as well as buffer substances and detergents, are adsorbed onto paper fleeces mounted below an application well. Heparinized blood (160 microL) applied to this well solubilizes the dry chemistry reagents. Blood cells are separated from plasma via a glass-fiber fleece. The immunocomplexes formed are concentrated within the reading zone by binding of the biotin-labeled antibody with streptavidine immobilized to the test device. Troponin T bound to the test device serves as a control. The detection limit of this assay is 0.18 microgram/L with a cross-reactivity with skeletal troponin T of 0.5%. In clinical analyses involving 25 healthy volunteers, 62 patients with chest pain but without myocardial ischemia, 35 patients with acute myocardial infarction, 24 patients with minor myocardial cell damage due to radiofrequency ablation, and 35 patients with unstable angina, the rapid assay was comparable to the troponin T enzyme immunoassay in regard to sensitivity and specificity.
Conclusions:
This newly developed assay allows accurate, rapid, and convenient diagnosis of acute myocardial cell necrosis.
More Related Videos
09:23Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Automated Microbial Diagnostics