[A rare case of coronary artery perforation by a PTCA guide wire complicating with postinfarction cardiac rupture after thrombolytic therapy]
Related Experiment Videos
Insights
A rare case of guide wire-induced coronary artery perforation during percutaneous transluminal coronary angioplasty (PTCA) led to cardiac rupture and tamponade, especially after thrombolytic therapy.
Area of Science:
- Cardiology
- Interventional Cardiology
- Cardiac Surgery
Background:
- Acute myocardial infarction necessitates timely intervention.
- Percutaneous transluminal coronary angioplasty (PTCA) is a common treatment for myocardial infarction.
- Thrombolytic therapy, like tissue plasminogen activator (t-PA), is used to restore blood flow.
Observation:
- A patient with extensive anterior wall acute myocardial infarction developed cardiac rupture and tamponade during emergency PTCA.
- The injury was caused by a guide wire used during PTCA, perforating the meandering left anterior descending artery (LAD).
- A small, oozing-type cardiac rupture was also noted near the apex.
Findings:
- Coronary artery perforation by a PTCA guide wire is a rare but serious complication.
- Meandering coronary arteries may increase the risk of guide wire perforation.
- Guide wire perforation can lead to significant hemorrhagic complications, including cardiac rupture and tamponade, particularly after thrombolytic therapy.
Implications:
- Urgent surgical repair of both the perforated coronary artery and the ruptured ventricle is crucial for patient survival.
- Awareness of this complication is important for interventional cardiologists, especially when treating patients with complex coronary anatomy or those who have received thrombolytic therapy.
- This case highlights the potential risks associated with PTCA in the context of thrombolysis and complex coronary anatomy.
Abstract:
We report a rare case of coronary artery perforation by a guide wire for percutaneous transluminal coronary angioplasty (PTCA) complicating with postinfarction cardiac rupture (oozing type). The patient had acute myocardial infarction on the extensive anterior wall and developed cardiac rupture followed by serious cardiac tamponade during the emergency PTCA several hours after tissue plasminogen activator (t-PA) given intravenously. The meandering left anterior descending artery (LAD) was found injured by a PTCA guide wire apart from a small oozing-type cardiac rupture near the apex. We repaired urgently the perforated LAD as well as the ruptured left ventricle. It is thus suggested that coronary artery perforation by a PTCA guide wire may occur on meandering coronary arteries and develop a serious hemorrhagic complication, particularly after thrombolytic therapy.