Related Experiment Videos
[Dislodgement of the ringed-graft--a case report]
1Department of Thoracic and Cardiovascular Surgery, Tohoku University School of Medicine, Sendai, Japan.
Abstract:
A 70-year-old man underwent replacement of the distal aortic arch which contained a huge aneurysm using a ringed graft. He died suddenly of hemoptysis 54 months following the operation. An autopsy revealed dislodgement of the spool on the posterior aspect of the aorta. Histologic examination of the dislodged portion of the ring showed complete disruption of the intima and elastic fibers of the media. There were minimal histologic changes in the anterior portion of the anastomotic site. It is postulated that the long, kinked graft might have caused the late ring dislodgement.